Customization: | Available |
---|---|
Type: | Normal Pressure Transmitter |
Structure Type: | Diffused Silicon Pressure Transmitter |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Applicable media | Liquid, gas and steam |
Pressure range | -100KPa~70MPa |
Accuracy | 0.075%, higher on request |
Stability | ±0.15% of URL for 5 years |
Temperature drift | ±0.03% of URL/10ºC |
Output signals | 4~20mA, Hart, PROFIBUS-PA for option |
Housing material | Aluminum14 |
Process connection | M20×1.5; G1/2; 1/2NPT; 1/4 NPT; Customization |
Protection class | IP66/67 |
Ex-proof | Exia II CT4, Exia III CT6, Exd IICT6 |
Power Supply | 10.5-55V DC 10.5-30V DC (recommend 24V DC) |
Ambient temperature | -40 to 85ºC, -40 to 80ºCfor LCD header |
Storage temperature | -45 to 85ºC, -40 to 80ºC for LCD header; |
Measurement | With display: 95*126*52 (mm) |
Without display: 95*115*52 (mm) | |
Net Weight | 1.7kg (without bracket or process connection) |
Model | Product Details | ||
WNK51 | Smart high precision pressure transmitter | ||
Code | Approval | ||
A | For non-hazardous areas | ||
1 | ExiaIICT6 | ||
2 | ExiaIICT4 | ||
3 | ExdIIBT6 | ||
For other approvals or more information, please contact with us | |||
Code | Output Code | ||
A | 4…20mA | ||
H | 4…20mA, HART | ||
P | PROFIBUS-PA | ||
F | FF | ||
Code | Display | ||
A | No display | ||
L | LCD | ||
Code | Housing; Cable entry; Protection | ||
A | Aluminum14, M20×1.5, IP66/67 | ||
B | Aluminum 14, G1/2, IP66/67 | ||
C | Aluminum14, 1/2NPT, IP66/67 | ||
Code | Sensor range, for gauge pressure | Code | Sensor range, for absolute pressure |
1C | 100mbar (10kPa/1mH2O) | 2C | 100mbar (10kPa/1mH2O) |
1E | 250mbar (25kPa/2.5mH2O) | 2E | 250mbar (25kPa/2.5mH2O) |
1F | 400mbar (40kPa/4mH2O) | 2F | 400mbar (40kPa/4mH2O) |
1H | 1bar (100kPa/10mH2O) | 2H | 1bar (100kPa/10mH2O) |
1K | 2bar (200kPa/20mH2O) | 2K | 2bar (200kPa/20mH2O) |
1M | 4bar (400kPa/40mH2O) | 2M | 4bar (400kPa/40mH2O) |
1P | 10bar (1MPa/100mH2O) | 2P | 10bar (1MPa/100mH2O) |
1S | 40bar (4MPa/400mH2O) | 2S | 40bar (4MPa/400mH2O) |
1U | 100bar (10MPa/1000mH2O) | 2U | 100bar (10MPa/1000mH2O) |
1W | 400bar (40MPa/4000mH2O) | 2W | 400bar (40MPa/4000mH2O) |
1X | 700bar (70MPa/7000mH2O) | 2X | 700bar (70MPa/7000mH2O) |
Code | Calibration, Unit | ||
1 | Sensor range, mbar/bar | ||
2 | Sensor range, kPa/MPa | ||
3 | Sensor range, mmH2O/mH2O | ||
4 | Sensor range, psi | ||
Code | Diaphragm material | ||
1 | 316L | ||
2 | Alloy C-276 | ||
X | Other special requirement | ||
For other special kind of diaphragm, please contact with us. | |||
Code | Process connection; Screw | ||
GA | Male thread G1/2, inner hole 3mm, 316 | ||
GB | Male thread G1/2, inner hole 11.4mm, 316 | ||
GC | Female thread G1/2, inner hole 3mm, 316 | ||
GD | Female thread G1/2, inner hole 11.4mm, 316 | ||
NA | Male thread 1/2NPT, inner hole 3mm, 316 | ||
NB | Male thread 1/2NPT, inner hole 11.4mm, 316 | ||
NC | Female thread 1/2NPT, inner hole 3mm, 316 | ||
ND | Female thread 1/2NPT, inner hole 11.4mm, 316 | ||
MA | Male thread M20×1.5, inner hole 3mm, 316 | ||
MB | Male thread M20×1.5, inner hole 11.4mm, 316 | ||
JX | Other special requirement | ||
For other special connection screw thread, please contact with us. | |||
Code | Process connection material | ||
3 | 316 | ||
H | Alloy C | ||
Code | Overvoltage protection | ||
A | No | ||
M | Overvoltage protection | ||
Code | Mounting bracket | ||
A | No | ||
U | Mounting bracket for pipe | ||
Typical model#: WNK51 AHL A1P21 MA3 AU |
Q: Are you manufacturer or trading company?
A: We are professional pressure/level/temperature measurement manufacturer with more than 13 years of experience. Our factory address is: 4/F, Bldg #6, No. 168, Xiangzhang Road, High-tech District, 230088, Hefei, Anhui province, China.